how many parts are IN a generator?


​   THE HONDA EU3000 GENERATOR

​This is a great little generator that has so many applications it will probably never become extinct.
That's why we need to combine it with an energy storage system to maximize it's capabilities at the same time preserving it's life.
Honda's powerful, commercial-grade OHV engine runs on regular gasoline—no need to mix with oil. The Oil Alert® feature automatically shuts down the engine if oil pressure reaches an unsafe level. Eco-Throttle® system also helps to increase fuel efficiency by allowing the engine to run only as fast as needed for the load. The totally enclosed body design helps to reduce noise. For outdoor use only.



​Honda EU3000 inverter/Generator
​TECHNICAL SPECS
  • ItemPortable Inverter Generator
  • Rated Watts 2800
  • Surge Watts 3000
  • Engine Brand Honda
  • Voltage 120VAC
  • Amps 25.0
  • Circuit Breaker Yes
  • Engine Size 196cc
  • Run Time @ Full Load 7.2 hr.
  • Run Time @ 1/2 Load 13.0 hr.
  • Sound Level dB 49 to 58
  • Fuel Tank Capacity 3.4 gal.
  • Starter Type Electric/Recoil
  • Wheel Kit Included No
  • Air Cleaner Type Foam
  • Low Oil Shut Down Yes
  • Length25-4/5"
  • Width18-9/10"
  • Height22-2/5"
  • Full Power Switch Yes
  • Fuel TypeGasoline
  • Outlets20A Duplex, 30A Locking
  • Parallel Configuration Capable Yes
  • Run Time Hour Meter No
  • Cylinder Material Aluminum
  • Generator Mfr. Warranty Details 3 yr.
  • Includes Battery
  • Standards EPA
  • CARB Compliant Yes
  • Series Super Quiet
  • Weight 165lbs
  • Outdoor ONLY
       SURE POWER SOLUTIONS      
      ENERGY STORAGE SYSTEM

When you need to use generators, installing a
Sure Power Energy storage system can result in 60-80% fuel reduction. It also greatly cuts labor costs to monitor and refill generators.
Sure Powers Energy Storage Systems, will allow the mobile site to draw from the electric grid and the generator only when the batteries reach 22% DOD or system capacity; then, the whole power output of the generator is used to charge the battery, rather than to operate the equipment.
The result* is a 50% reduction in fuel use, a return-on-investment in less than 16 months and a continued 50% decrease in operating costs.
Savings are further enhanced through lower fuel-resupply costs and fewer maintenance demands.

​
​FUEL FREE SOLAR MOBILE
SUREPOWER ENERGY STORAGE SYSTEM 
​TECHNICAL SPECS
  • Item Portable Energy Storage/Inverter 
  • Rated Watts 4000 Continuous
  • Surge Watts 12,000  52amp 20sec.
  • Engine  NA   Li-Ion energy storage
  • Voltage120VAC and 230VAC
  • Amps52amps for 20sec. 33.3amps continus
  • Circuit Breaker Yes
  • Remote monituring with self diagnostics
  • Run Time @ Full charge 13.2 hr. NO SUN
  • Run Time @ 1/2 Load 7.1 hr.  NO SUN
  • Sound Level  NO SOUND
  •  3082 Watt Hours  Li-Ion
  • Starter Type  On/Off Button
  • Wheel Kit Included  YES
  • NA
  • NA
  • Length25-4/5"
  • Width18-9/10"
  • Height22-2/5"
  • Full Power SwitchYes
  • Fuel Type SUN/Solar Voltaic
  • Outlets20A Duplex, 30A Locking
  • Parallel Configuration Capable  Yes
  • Run Time Hour Meter  YES
  • Full energy logging and tracking
  • Power System Mfr. Warranty Details 3 yr.
  • YES
  • StandardsEPA
  • YES
  • Super Series Super Quiet 
  • 150amp DC Input/Output for vehicle charging and emergency jump start
  • Capable of being fast charged with 230vac generators or 230 vac shore line
  • Can be used in confined spaces  "NO FUMES"
  • No Moving Parts
  • 10 year expected lifetime
  • Weight 54LBS
  • Indoor Outdoor Use
  • Internal Li-Ion management for extended capacity life and safety
Picture
   


         

​ What is an Inverter Generator
?

Generators are generally lighter and smaller than conventional generators. They also cost three to five times more than do conventional generators.
Conventional generators must run at 3,600 RPM constantly in order to generate electricity. Inverter generators, on the other hand, can run at variable speeds depending on the electrical demand. This allows the inverter generator to run at slower speeds most of the time. This saves fuel, and it also greatly reduces the amount of noise produced by the generator.
As a general rule, inverter generators produce cleaner power. This basically means that there is a reduced risk of fluctuations. This cleaner type of power is necessary if the generator is being used to power sensitive electrical equipment, such as high-definition televisions, computers, hospital equipment and specialized equipment in a laboratory setting.
Many inverter generators now come with surge-protecting ground-fault circuit interpreters, which guard against shock and provide protection against spikes, surges and brownouts.